Детская офтальмология и косоглазие. BCSC, раздел 6 (2024–2025)

Video 1-2) or vanis hing optotype (Cardiff Acuity Test) on one half, and a homogeneous gray area of equal mean luminance on the other. The observer notes where the child looks upon being shown the card, then checks to see whether it was toward the stimulus. As the stripes in the grating or figure outline become finer (higher spatial frequency), fixation be hav ior approaches chance at the child’s resolution threshold. Other preferential looking tests of grating acuity include the LEA Grating Acuity Test (LEA Test Intl/Good- Lite Com­ pany), and Patti Stripes Square Wave Grating Paddles (Precision Vision). Table 1-3 shows the average grating resolution acuity at dif fer ent ages.

T able 1-3 Monocular Grating Resolution Acuity Test Results for Forced- Choice Preferential Looking Using Teller Acuity Cards

Age (Mo)Mean Grating Acuity (Cycles/Degree)aSnellen Fraction Notation of Similar Spatial Frequencyb
10.9420/640
42.6820/220
65.6520/110
126.4220/93
249.5720/63
3621.8120/28

a One cycle = 1 pair of black- and- white grating stripes. The number of cycles per degree of visual angle is a mea sure of spatial frequency.

b Even for a similar spatial frequency, grating resolution acuity is not comparable to optotype recognition acuity. Snellen fraction notations are provided only as a familiar indicator of spatial frequency. Snellen fraction notation denominators are rounded to 2 significant figures.

Information from Mayer DL, Beiser AS, Warner AF, Pratt EM, Raye KN, Lang JM. Monocular acuity norms for the Teller Acuity Cards between ages 1 month and 4 years. Invest Ophthalmol Vis Sci. 1995;36(3):671–685.

Рисунок со страницы 33

VIDEO 1-2 Teller Acuity Card testing.

Courtesy of Lee R. Hunter, MD.

Рисунок со страницы 33

Visual evoked potential

The visual evoked potential (VEP) is an objective tool for quantifying visual function that does not rely on a child’s verbal or motor responses. In this test, electrodes are placed over the occipital lobe to mea sure cortical electrical signals produced in response to a visual stimulus (see BCSC Section 5, Neuro- Ophthalmology). The sweep VEP is a method for estimating visual acuity in preverbal children. The child views a series of bar or grid patterns of varying spatial frequency. The amplitude of the VEP waveform decreases with increasing spatial frequency, yielding a threshold spatial frequency estimate of grating resolution acuity. VEP estimates of monocular grating resolution acuity in infants are higher than estimates based on behavioral (preferential looking) tests; based on visual cortical responses, the infant visual system can re­ solve a spatial frequency of about 5 cycles per degree at 1 month of age and well over 10 cycles per degree by 6 months of age (compare to Table 1-3 for results from preferential looking tests).

Hamer RD, Norcia AM, Tyler CW, Hsu- Winges C. The development of monocular and binocular VEP acuity. Vision Res. 1989;29(4):397–408.

Dynamic Retinoscopy

Noncycloplegic retinoscopy at near is a way to assess accommodation. In an emmetropic child with normal accommodation, the retinoscopic reflex will be close to neutralized if the child is focused appropriately on a near target located at the examiner’s working distance. Because the examiner can also assess how quickly the refractive state changes during a switch from far to near fixation, this technique is often termed dynamic retinoscopy. A poor accommodative response may indicate the need for hyperopic correction or a near- point add. Hypoaccommodation occurs more frequently in children with Down syndrome or ce re bral palsy than in the general pediatric population.

Visual Field Testing

Visual fields can be assessed once visual fixation has developed (usually by 4 months of age). If the introduction of a peripheral target while the child is fixating on an in ter est­ ing central target induces a saccade toward the peripheral target, this indicates vision in the corresponding hemifield. Confrontation visual fields can be approximated in children old enough to identify or count fin gers placed in each peripheral quadrant. School- aged children can often be evaluated with manual or automated perimetry.

Pupil Testing

The pupillary light reflex is not reliably pre sent until approximately 30 weeks’ gestational age. Pupils are usually miotic in newborns and gradually increase in size until preado­ lescence. Accurate pupil testing in young children is complicated by the smaller pupil and difficulty controlling accommodation. Pupil evaluation can be facilitated by careful observation, easily accessible control of room lights to allow continued observation dur­ ing changes in room illumination, and the use of appropriate distance-fixation targets. Digital photography can also be useful for observing and documenting pupil size and symmetry.